HomeProductsHG Thermal Awning Windows (TBAW Series)
CodeMark Certified -- CMNZ70173

HG Thermal Awning Windows (TBAW Series)

Extra High Wind | Low-E DGU Argon | R0.46ID: HG-TBAW-001 to HG-TBAW-006 / HGTR-TBAW

Thermally broken aluminium awning window assembly, top-hinged outward opening, with Low-E double glazed insulating glass unit (DGU) filled with argon gas. Customised to individual client specifications including dimensions and glass type.

HG Thermal Awning Windows (TBAW Series)

Click thumbnails to enlarge detail views

BPIR: Information below is disclosed per Building (BPIR) Regulations 2022, Schedule 2 -- free of charge, no login required. Click any section to expand.

Thermally broken aluminium awning window assembly, top-hinged outward opening, with Low-E double glazed insulating glass unit (DGU) filled with argon gas. Customised to individual client specifications including dimensions and glass type.

Intended use: External windows for residential and light commercial buildings. Suitable for timber-framed buildings per NZS 3604:2011 or specifically designed per B1/VM1. Certified for Extra High wind zones and any exposure zone except microclimates.

Product Identifier: HG-TBAW-001 to HG-TBAW-006 / HGTR-TBAW

This product holds CodeMark Product Certificate CMNZ70173, issued under section 19(1)(d) of the Building Act 2004 by Bureau Veritas Australia Pty Ltd (JAS-ANZ accredited). BCAs are legally required to accept this certificate as establishing compliance with the relevant clauses of the New Zealand Building Code. The product is tested to SNZ TS 4211:2022 (window classification), with glazing certified to AS/NZS 2208:2023 (safety glazing) and NZS 4223.2:2016 (insulating glass units) under CSi PAS-Mark Licence #7564. Thermal performance is independently verified by BRANZ (Report DC17865-02-001).

NZBC Clauses
B1 Structure (B1.3.1, B1.3.2, B1.3.3(a,h,j), B1.3.4)B2 Durability (B2.3.1(b), B2.3.1(c) for hardware)E2 External Moisture (E2.3.2, E2.3.7)F2 Hazardous Building Materials (F2.3.1, F2.3.2, F2.3.3)G4 Ventilation (contributes to G4.3.1, G4.3.3)G7 Natural Light (contributes to G7.3.1, G7.3.2)H1 Energy Efficiency (contributes to H1.3.1, H1.3.2E)
Test / PropertyResult / Value
Wind Resistance (SLS)1515 Pa -- Extra High (EH)
Wind Resistance (ULS)2500 Pa -- EM 7
Water Penetration Resistance291 Pa -- H (Non-exposed)
Thermal Performance (R-value)R0.46 (average houselot, BRANZ DC17865-02-001)
Centre of Glazing U-value1.66 W/m²K (for R0.46 target)
Visible Light Transmittance80% (Low-E XETB0180, ISO 9050:2003)
Glass CertificationCSi PAS-Mark Licence #7564 -- AS/NZS 2208:2023, NZS 4223.2:2016
Profile Alloy6063-T5 powder coated (min 82 μm, SDBZ-JZ2409063)
Model IDMax Frame Size (W x H)
HG001_TBAW_1M1340 × 1400 mm
HG002_TBAW_2FM2400 × 1640 mm (sash 1020 × 1640)
HG003_TBAW_1F2040 × 2040 mm
HG004_TBAW_3M/FM2440 × 1640 mm
HG005_TBAW_3MM/F2240 × 1840 mm
HG006_TBAW_3F/MM2240 × 1840 mm
HGTR_TBAW_6MF/FF/MF3040 × 2145 mm

Get a Quote for This Product

Upload your building consent drawings and we'll prepare a detailed quote including this product.

Upload Plans & Quote
Thermal Break Quality

Technoform thermal break strips -- the same polyamide PA66 GF25 insulating barrier used by leading European window manufacturers. We don't cut corners on the component that matters most for thermal performance.

Technoform Group · Germany · ISO 9001 certified

Certifications

CodeMark CMNZ70173
Bureau Veritas -- BCAs must accept
CSi PAS-Mark #7564
JAS-ANZ accredited, ISO/IEC 17065
BRANZ Tested
Independent thermal performance
ISO 9001
Quality management system
View all certifications