Building Code Compliance
Three Pathways to Compliance
01
CodeMark Certificate
Deemed to comply
BCAs must accept CodeMark Certificate CMNZ70173 as establishing compliance with the covered NZBC clauses (B1, B2, E2, F2, G4, G7, H1). No producer statement required.
02
Acceptable Solution
H1/AS1 schedule or calculation
Use BRANZ-verified R-values in your H1/AS1 schedule: TBAW R0.46 (DC17865-02-001), AW R0.37 (DC17572-04-001), SD R0.41. Values per NZS 4218:2009.
03
Alternative Solution
Engineer-led, project-specific
For configurations outside CodeMark scope. HG supplies CSi schedules, BRANZ reports, glass test reports, and profile specifications to support the engineer's assessment.
PrimaryBPIR Declaration
HG System Limited — BPIR Declaration V1.0
HG System Limited (self-declaration per BPIR Regulations 2022)
Scope: Full product range: TBAW, AW, SD, HD series — aluminium windows & doors
Standard: Building (Building Product Information Requirements) Regulations 2022
PrimaryCodeMark Product Certificate
CodeMark Certificate CMNZ70173
Bureau Veritas Australia Pty Ltd (JAS-ANZ)
Scope: HG Aluminium Windows & Doors — full range
Standard: Building Act 2004, s.19(1)(d) — covers B1, B2, E2, F2, G4, G7, H1
CSi PAS-Mark Certificates
C1 — AS/NZS 2208:2023
CSi (JAS-ANZ, ISO/IEC 17065)
Scope: Safety glazing
Standard: AS/NZS 2208:2023
C2 — NZS 4223.2:2016
CSi (JAS-ANZ, ISO/IEC 17065)
Scope: Insulating glass units (DGU)
Standard: NZS 4223.2:2016
C3 — SNZ TS 4211:2022
CSi (JAS-ANZ, ISO/IEC 17065)
Scope: Window & door classification — wind, water, thermal
Standard: SNZ TS 4211:2022
CSi Product Compliance Schedules
S1 — Thermal Stacker Door
CSi Licence #7564
Scope: Thermal stacker door
Standard: SNZ TS 4211:2022
S3 — Hinged Door (Inward)
CSi Licence #7564
Scope: Inward hinged door
Standard: SNZ TS 4211:2022
S4 — Hinged Door (Outward)
CSi Licence #7564
Scope: Outward hinged door
Standard: SNZ TS 4211:2022
S7 — Combination Top-hung & Sliding
CSi Licence #7564
Scope: Combination unit
Standard: SNZ TS 4211:2022
BRANZ Thermal Performance Reports
DC17865-02-001 — R0.46 (TBAW series)
BRANZ
Scope: Thermally broken awning windows — average houselot R-value per NZS 4218:2009
Standard: NZS 4218:2009 (flixo modelling)
DC17572-04-001 — R0.37 (AW series)
BRANZ
Scope: Standard awning windows — average houselot R-value per NZS 4218:2009
Standard: NZS 4218:2009 (flixo modelling)
Verify CMNZ70173
building.govt.nz — MBIE Register of Product CertificatesBPIR Compliance